Design Features of Canned Retro Pumps [FISB-000T2]] replace your existing mechanical seal and air cooled motor. It couples directly to your existing pump case, allowing you to keep your existing pump and eliminate the problematic mechanical seal.
Key Benefits:
Keep your existing pump installation
No mechanical seal means no leakage
Inherently safe
Double layer pressure boundary containment
Self-lubricated bearings – no external lubrication system needed
Eliminates pump and motor alignment – common shaft
Thrust bearing provides reliability during upset pump conditions
Low noise
Codes & Specifications
Operating Data
MOTOR
US
SI
Power
50HP
335kW
Voltage
575V
575V
Poles
2, 4
2, 4
VFD Compatible
Yes
Yes
Design Pressure
0-6000+psig
0-415 bar
Design Temperature
750ºF
400ºC
PUMP
US
SI
Flow
Up to 3,000* USgpm
680m3/hr
Head
Up to 1000*ft
305m
*higher available on request
Codes and Compliances:
ASME Section VIII and III including stamp (N)
Hydraulic Institute
Pressure Equipment Directive (PED)
10CFR21 and 10CFR50 (Nuclear)
RCC-M and RCC-E
Other international codes as required
Company responsible for product safety: PUMPA,a.s. U Svitavy 54/1, Brno 618 00, CZ e-mail: info@pumpasupply.com